Goodman furnace: Open Primary Limit Switch
Try DIY first, then call a pro
What does 4 flashes mean on a Goodman furnace? The high-limit opened — the furnace overheated. The circulator blower runs until the limit closes. Code: four short flashes.
GOOD NEWS: THE FIRST CHECKS ARE FREE AND TAKE MINUTES.
Try these first — in this order
Replace the filter and open every supply/return vent — 5 minutes.
Repeated overheating cooks heat exchangers (a CO-risk precursor). Recurring code 4 = service call. DIY part cost: $5–25 / $10–25 — a pro visit for this class of fault typically runs $150–350.
What causes it (in order of likelihood)
- Dirty filter or restrictive ductwork (official first cause) DIY-CHECKABLE
- Faulty limit switch TECH
- Weak blower motor or failed capacitor TECH
Parts referenced by this code
Always match parts against your model's parts list — part numbers vary within a series.
Applies to
GMS8 · GDS8 · GHS8 · GMSS96 · GMH8 · GDH8
Different Goodman generations use different code maps. If your series isn't listed, don't assume this meaning — check your blower-door label.
Verified against Goodman GMS8/GDS8/GHS8 Service Manual (RS6612006), p.42 — “four short flashes followed by a pause”
Verified against Goodman GMSS96 Service Manual, p.32
Last verified 2026-07-06 · how we verify